Type: Central Air Conditioners
Capacity: as Customized
Certification: CCC
China Energy Efficiency Standard: Level 1
Cooling/Heating: Cooling/Heating
Power Source: Electrical
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HJK Series
Condition
New
Feathers
Energy Saving, Heat Recovery Air Handling System
Transport Package
Standard Seaworth Plywooden Case
Specification
Typical Flexible Combinations
Trademark
HOLTOP
Origin
Beijing, China
Production Capacity
10000 PCS/Year

Product Description

Overview/ Quick Details
Type:Air Handling Unit
Mounting:Floor Standing
Place of Origin:Beijing, China (Mainland)
Brand Name:HOLTOP
Operating Voltage:380/400 VAC
Application: Shopping mall/shopping center/shopping plaza/commercial building
Solutions: offer solutions for commercial buildings,Auto industry,Medical and pharmaceutical industry,printing and food industry, VOC treatment and enviorment protection,wind turbine nacelles and data centers,etc.

Cabinet material:Thermal insulation double skin sandwich panel 25mm/50mm
Airflow:1000~200000CMH
Fan type:Centrifugal fan/Plug fan
Function:Cooling/heating/ventilation/heat recovery
Cooling capacity:Customized
Refrigerant:R407C/R410A/R134A/R22
Power supply:380~420V/3PH/50Hz

Fresh air handling units, High efficiency cabinet air handling unit, hvac air handling unit
Product name
Air handling unit
Material
Stainless steel
Function
Heat recovery,adjust cold/heat/humidity
Application
Factory,Mall,Restrant, Hotel,Hospital, etc
Filter class
G4+F7+H10
Place of origin
Beijing,China

 Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units
 

Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units
 

 

Selection Table of AHU
Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units

 

Working principle

1/Both supply fan and exhaust fan are built inside tobring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor space in natural comfort.
2/Built-in heat exchanger (rotary heat exchanger or plate heat exchanger) transfers energy contained in the outgoing indoor air to the coming fresh air,thus fresh air is precooled or preheated.
3/Various functional sections such as filter section,cooling/heating section, humidifying section etc.can be combined together to meet different air treatment requirements.

 

Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units

 

Judging left or right type

Look at the direction of airflow supplied to indoor, it's left type if water pipes are located on the left side of the unit; otherwise, it's a right type. For standard AHU, service door, wiring port and water pipe locate on the same side.

Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units
 

 

Main features

1/ Up-down layer construction, concise, compact.
2/ Rotary heat exchanger(RHE) as a basic part. Humidifying section, coil section etc. selectable as per requirements.

 

Typical Combinations

Combination mode 1:
Wheel + Coarse filter (medium filter) + Cooling coil (heating coil)+ Humidification + Fan

Combination mode 2:
Plate heat exchanger + Coarse filter (medium filter) + Mixed air +Cooling coil (heating coil) + Fan

Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units
 

 

Rotary heat exchanger (heat recovery wheel) is mainly used in building ventilation or in the air supply/discharge system of air conditioning equipment. The wheel transfers the energy (cold or heat) contained in exhaust air to the fresh air supplied to indoor.It's a piece of important equipment and a key technology in the field of construction energy saving.

 Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units
 

 

 

Rotary heat exchanger section

1. Rotary heat exchanger is composed of heat rotor(wheel), frame, drive system, double purge sector and sealing parts etc..
2. Supply air(SA) passes through half of the wheel, exhaust air(EA) passes through reversely the rest half of the wheel, meanwhile the wheel is rotating driven be the drive system. Thus, the wheel can be self-cleaning.
3. Drain pan is equipped under the wheel, in case condensed water occurs from fresh air in summer or return air in winter when their temperature is decreasing. Meanwhile, make sure the drainpipe is expedite and waterseal is installed.

4. Ice jam might occur on the exhaust side when operating in very cold area, if so, rotary speed reduction or turn-on of bypass is required to ensure safe operation of the wheel.
5. On some occasions with strict cleanness requirement, to minimize the carryover from return air to supply air, exhaust fan shall be placed in the leaving section of the exhaust side to create passive pressure, and the pressure shall be lower than that of supply side, so that the double purge sector can perform more effectively.
6. For easy transportation or easy installation in limit space, the wheel can be cut into segments.

Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units

                     

FAN SECTION

We offer different types of fans such as direct driven centrifugal fan, belt driven DIDW forward centrifugal fan, and belt driven DIDW backward centrifugal fan etc.

 

Holtop Ahu Air Handling Units HVAC System Air Conditioning Terminal Units
 

 

Air filter

In order to ensure heat exchanging efficiency and cleanness, combination of G3 coarse filter and F5 medium filter is selected as standard configuration in HJK AHU