Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators

Material: Aluminum
Usage: for Air Conditioner, Engergy Recovery Ventilation System
Flow Direction: Cross-Counterflow
Pressure: Low Pressure
Certification: ISO
Heat Recovery Efficiency: 70%
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TP series
Airflow
150~2000CMH
Controller
LCD Standard or Intelligent Control Optinal
Feature Function
Automatic by-Pass Function
Heat Exchanger Type
Plate Heat Exchanger
Heat Recovery Core
Enthalpy Heat Exchanger
Feature
High Static Pressure
Power Supply
220~230V/50Hz/1phase
Weight
28-189kg
Principle
Recuperative Heat Exchanger
Application
Commercial or Residention Ventilation System
Heat Transfer Surface
Plate Heat Exchanger
Transport Package
Seaworth Wooden Cases
Specification
ISO9001: 2008, ISO14001, OHSAS18001
Trademark
HOLTOP or OEM
Origin
Beijing, China
HS Code
8451830000
Production Capacity
100, 000PCS/Year

Product Description

 


Eco design DCTP series high efficiecnt energy heat recovery ventilator

Product name ERV HRV Recuperator 
Brand Holtop
Material Stainless steel
Function Exchanege the air and keep the air quality.Save energy and heat
Application Home,office,factory,plaza,toilets and other house
Airflow 150-2000 m3/h
Place of origin Beijing,China
Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators
 Specification:
Model                  Airflow   (m3/h) External pressure
(Pa)
 
Enthalpy Efficiency(%)
Summer,     Winter
Temp. Eff.(%) Noise
dB(A)
Volt.
(V)
Current
(A)
   
Model L,     M,    H L,M,  H L,M,   H L,M,H L,  M,   H L,  M,   H   Current
(A)
Iuput
power
(W)
N. W.
(Kg)
XHBQ-D1.5TP 115,150,150 34,58,75 67,63,63 74,70,70 77,75,75 22,24,26 220 0.5 105 25
XHBQ-D2.5TP 165,250,250 30,70,85 67,63,63 73,70,70 77,75,75 22,26,27 220 0.56 117 29
XHBQ-D3.5TP 270,350,350 36,60,90 67,66 ,66 72,69,69 77,75,75 25,29,31 220 0.72 150 37
XHBQ-D5TP 360,500,500 30,60,100 68,62,62 72,67,67 78,75,75 25,31,33 220 0.96 200 43
XHBQ-D6.5TP 515,650,650 25,40,70 64,65,62 70,68,68 77,75,75 30,34,35 220 1.4 295 64
XHBQ-D8TP 625,800,800 60,98,120 68,65,65 74,71,71 77,75,75 32,36,38 220 1.7 355 71
XHBQ-D10TP 780,1000,1000 25,35,85 68,65,65 74,71,71 77,75,75 31,36,38 220 2.1 440 83
XHBQ-D15TP 1250,1500,1500 20,45,75 68,65,65 74,71,71 77,75,75 31,39,41 220 3.4 710 165
XHBQ-D20TP 1700,2000,  2000 20,25,60 68,65,65 74,71,71 77,75,75 34,39,41 220 4.2 880 189
Features                  
-  Energy saving BLDC motor, 10 speeds control
-  High efficiency enthalpy heat recovery, more comfortable indoor climate

-  Intelligent control system, optional CO2 and humidity control function, external control and BMS control available

-  Auto bypass, intelligent controlled by outdoor temperature

Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators
Energy efficiency class of A according to regulation EU.No.1254/2014.


Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators
 

Easy installation and maintenance        

The unit can be installed either horizontally or upside down in accordance with the conditions of location. A
450mm square inspection port enables filters and heat exchangers maintenance to be performed with ease.

Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators

Intelligent Controller  for option

Functions

- Airflow rate switch (10 speeds)
- Temperature display
- Automatic bypass
- Weekly timer
- Data memory/power to restart
- Automatic defrosting
- Electric heater defrosting (optional)
- Comfortable heating (optional)
- External ON/OFF
- CO2 concentration control 
- BMS integration
- Working condition monitor
- Humidity control (optional)
- Free night cooling

Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators

 

Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators
Air to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery VentilatorsAir to Air Cross-Counter Flow Plat Sensible Heat Energy Recovery Ventilators
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters