• Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump
  • Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump
  • Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump
  • Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump
  • Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump
  • Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

After-sales Service: on-Line Support
Warranty: 1
System Structure: Air Sources Heat Pump
Heat Source: Air Sources Heat Pump
Heat Medium: Hot Air Heating System
Material: Steel
Samples:
US$ 8000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HFW-65HA1-R
Other Optional Specification
65kw, 130kw
Transport Package
Sea Worth Packing
Specification
65KW
Trademark
HOLTOP or OEM or No logo
Origin
Beijing, China

Product Description

Holtop Total Heat Recovery Type Air Cooled Chiller Heat PumpHoltop Modular Air Cooled Chillers are our latest product based on over twenty years of research & development, technology accumulation and manufacturing experience which helped us to develop chillers with stable & reliable performance, greatly improved evaporator & condenser heat transfer efficiency. In this way it's the best choice to save energy, protect environment and achieve comfortable air conditioning system.

Holtop Modular Air Cooled Chiller can widely used in hotels, hospitals, shopping malls, office buildings, cinemas, metal industry, oil & chemical industry, manufacturing industry, electronics industry, electric power stations etc.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

Product Feature

1. Integrated Protection: 

Designing more than 10 safety protection functions, which can ensure chiller unit and the system operation in all-round protection. The unit can be controlled through a multi-variable monitoring system to ensure the unit with stable and efficient operation.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

2. Wide Temperature Range of Application, Worry-free of Operation:

Chiller unit is suitable for operation in a wide outdoor temperature range, from -20C~48ºC.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

3. Chiller Unit Operation When Has Fault:

A single unit is designed with multiple compressors. When one of the compressors fails, the rest of the compressors in the system can still operate normally without affecting the operation of the whole system.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

4. Modular Combination: 

The chiller adopts modular combination design and does not need to set the master or sub-master unit. Each combination is able to connect a maximum of 16 units, even they are made of different models, to meet the variable demands of different buildings.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

5. Step Starting:

Starting all units in steps, in order to lower the starting current, reduce the shock to power grid, and avoid affecting the security of other electrical equipment.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

6. Flexible Application:

Investment: Add extra units into combination at any time, convenient for multiple stages of investment

Transportation: The volume of each unit is compact, can be transported individually, does not need a crane at the project site, can save transportation cost.

Installation: Does not need machine room or cooled water system, only somewhere with good ventilation. The water pipes are designed on side of the unit, which can be easy for chilled water connection and save installation space.

System: At the water circulating system, besides the standard use of the constant flow system, it is optional to use the primary pump with a variable flow system, and the variable speed control cabinet is optional to select.

7. Smart Defrosting System:

By sensing with the multi-variables system to have accurate judgement on the situation of frosting, the chiller itself can be able to choose the best time to enter or exit defrosting, to avoid insufficient defrosting or over defrosting. In a duplex system, the units can achieve alternate defrosting. When heating under extreme low-temperature conditions, setting manual defrosting for better performance.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

8. Intelligent PLC Control System:

The PLC control system combines the simplicity and convenience of the wired control system and the advantages of the centralized group control system to achieve chiller group centralized control. One PLC control system can manage 1 to 8 groups. Each group can control 1 to 16 pieces of modular chillers. The system can control up to 128 modular chillers. The control system also delivers various features such as group mode switching, temperature adjustment, on/off control, etc to adopt numerous applications.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

9. Free Access to Building Automation System:

Standard RS485 building communication interface comes with open access to standard ModBus communication protocol. The device can be easily connected to the building control system (BAS) for centralized control, easy to achieve intelligent control, avoid unnecessary energy waste, and save air-conditioning operating costs.

Holtop Total Heat Recovery Type Air Cooled Chiller Heat Pump

Holtop Total Heat Recovery Type Air Cooled Chiller Heat PumpHoltop Modular Air Cooled Chiller Parameters:
Holtop Total Heat Recovery Type Air Cooled Chiller Heat PumpHoltop Total Heat Recovery Type Air Cooled Chiller Heat PumpHoltop Total Heat Recovery Type Air Cooled Chiller Heat Pump

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters