Type: Air-Cooled
Cooling Water: Industrial Water
System Type: Closed System
Fans Species: Frequency Fan
Noise Level: Low
Application Fields: Medical Equipment
Samples:
US$ 400/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
XHBQ-D2THC
Certification
ISO
Condition
New
Install Type
Suspended Erv
Heat Recovery Core
Cross Counter Flow Plate Heat Exchanger
Core Made of
Er Paper
Airflow Rate
150~2000CMH
Power Supply
220~230V/50Hz/1phase
Control System
Remote Standard or Intelligent Contorl
Application
Commercial and Residential
Feature Funcion
by-Pass Function
Delivery Date
3 Weeks
Usage
Energy Recovery Ventilation
Transport Package
Wooden Pallet and Wrapping Film
Specification
ISO9001, ISO14001
Trademark
HOLTOP
Origin
Beijing, China
HS Code
841583000
Production Capacity
100, 000 PCS

Product Description

 
Holtop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation System
Eco-Vent Energy Recovery Ventilator
 Airflow Range: 150-400CMH
 

INTRODUCTIION OF HOLTOP ERVs

1) Enthalpy Recovery HRV in Ventilation System
2. High efficiency, over 70%
3. Perfect silence design
4. Slim thickness, easy to install in the ceiling
5. High airproof feature and easy maintenance
6. With or without PM2.5 Filter is optional
7. DC motor or AC moter is optional
8. Standard controller or intelligent controller is optional

Controller optional functions

1. Temperature display
2. Automatic bypass
3. Electrical heater
4. Defrosting
5. External ON/OFF
6. CO2 concentration control
7. Smart alarm
8. Data memory
9. Weekly timer
10. Airflow adjustment

Ceiling Type Heat Recovery Ventilator Features


Holtop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation System
Holtop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation System
Holtop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation System
* Effective Ventilation
Introduces outdoor fresh air into indoors, meanwhile exples the indoor stale air to outdoor, which makes you feel the comfort of the nature.

* High efficiennt energy recovery
The bult-in high efficient heat exchanger can recovery the energy from outgoing indoor air to coming fresh air while ventilatin. It can recovery over 70% energy

* Perfect silence design
It is deisgned with the worldwide fashiionable structure and manufactured by the accurate molidings. According to the principle of hydrokinetics, it achieves the perfect silent effect by using the micro-punch anechoic technology.

* Air filtration and pruification
The inner air filters are professionally designed to remove the pollutants of the incoming air, providing you the fresh and clean air.

* By-pass function
By-pass function enables the unit to make antual ventilation in suitable climates, which can prolong the service life of the heat exchanger

* High airproof feature and easy manintenance
The heat exchangers is connected with the equipment by the in-mold rail, and embedded with the special soft and dense sealing materials. It can be drew out by hand and is easy to maintain. At the same time, it can ensure that tht fresh air and exhaust air are completely separated, avoiding the cross pollution.

Welcome to inquire our ERVs featured Quiet Operation.
Model                Airflow(m3/h) External pressure
(Pa)
Enthalpy Efficiency(%)
Summer,   Winter
Temp. Eff.(%) Noise Volt. Current Input
power
N. W.
Model L,      M,    H L,   M,   H L,  M, H L, M, H L,  M, H L, M, H (V) (A) (W) (Kg)
XHBQ-D2THC 150 ,200,200 60,70, 75 60,55,55 63,59,59 75,70,70 22, 25, 27 220 0.5 105 23
XHBQ-D3THC 250, 300,300 75,82, 85 62,57,57 65,61,61 73,68,68 23, 27, 30 220 0.56 117 25
XHBQ-D4THC 350, 400, 400 80,85, 88 62,57,57 65,60,60 74,69,69 25, 29, 32 220 0.72 150 31

Holtop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation System
Holtop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation SystemHoltop Residential Style Fresh Air Duct Ventilation Heat Recovery Ventilation System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters