Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital

Product Details
Customization: Available
Type: Air Handling Unit
Operating Voltage: 380/400 VAC
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
  • Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
  • Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
  • Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
  • Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
  • Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
Find Similar Products

Basic Info.

Model NO.
HJK
Noise Level
Ordinary
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
10~15 years
Certification
ISO, CCC
Condition
New
Install Type
Floor
Panel Type
Single or Double Skin
Airflow
2000-10000 CMH
Panel Thickness
25/ 50mm
Heat Recovery Section
Plate or Eurovent Rotary Heat Exchanger
Filter
Coarse: G2, G3, G4, Medium:F5~F8
Heating and Cooling System
Optional
Control System
Optional
Cooling Method
Chilled Water
Feasures
Energy Recovery+Air Handling
Transport Package
Wooden Pallet
Specification
ISO9001, ISO14001, OHSAS18001
Trademark
HOLTOP
Origin
Beijing, China
HS Code
8415822000
Production Capacity
100, 000sets/Year

Product Description


Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
Introduction of Air Handling Unit,


1)Suspended on the ceiling or Vertical
2)Multi-functional
3)Heat recovery functions (Eurovent Heat Exchanger)
4)Excellent thermal insulation
5) Airflow 2000~100000CMH

Main features
1) Equipped with supply fan and exhaust fan, brings in fresh air and exhausts out stale indoor air as well.
2) Equipped with rotary heat exchanger, recovers energy from outgoing indoor air, to save operating cost to the max.
3) Thin height, easily installed in the ceiling space.

Housing construction
1) Double skin panel
25mm thick, inner skin made of galvanized steel sheet, outer skin color steel sheet, between skins is sandwiched with high density fireproof PU with thermal coefficient below 0.0199W/m Degree.
2) High air tightness
Double inlaid sealing system to tightly join the framework and panels, total air leakage rate below 3%.

Supply fan and exhaust fan
Outer rotor motor, direct driven centrifugal fan, dynamic balance, compact and low noise level.

Filter
Plate type(G4) coarse filter as standard configuration. (Bag filter F5~F8 available as per request of customer). Draw-push installation, easy maintenance.

Eurovent Rotary heat exchanger
Holtop total heat exchanger (enthalpy recovery wheel) is made of aluminum foil coated with 3A molecular sieve, which enables the wheel to exchange both temperature and humidity, in another word, to recover both sensible and latent heat.

Operation and maintenance
1. AHU is powered by TN-S power supply system, i. E. AC3~380V+N+PE.
2. Check and make sure motor runs at right direction and freely. Run the unit after all the electric parts are checked without fault by a professional.
3. Commissioning is required before putting the equipment into use. Motors should be running under rated electric current.
4. Cooling & heating coil should use clean demineralized water as medium, working pressure ≤ 1.2MPa.
5. Drain out the water in the coil in winter, and blow away the remains water as far as possible. In case remains water can not be blew away, inject antifreeze into the coil.
6. Examine the filter regularly, clean or replace it if resistance comes to the end resistance. Air-dry the washed fil- ter totally before reuse.
7. Fully clean or maintain the unit after each 1 or 2-year operation. Clean the coils using compressed air or high pressure water.
 
No. Part Name Material Description
1 Unit panel external plate material is colorful steel sheet t0.4mm, specialized for air conditioning elegant apprearance, dignity,high corrosion resistance
inner plate material is galvanized steel sheet t0.5mm adopt spangle-free
2 Panel heat preservation high pressure foamed polyurethane t 50mm good insulation performance, high strength, foaming ratio 40Kg/m³
3 Other heat preservation polyethylene foaming good insulation performance
4 Unit frame t 1.0mm  colorful steel sheet frame corrosion resistance, long product life,  high strength
5 Copper tube of cooling coil Ø12.7mm copper tube,  wall thickness 0.41mm phosphorized seamless copper tube, good heat-transfer
 
6 Cooling coil fin Ø12.7mm copper tube, adopt aluminium foil t0.15mm aluminium foil surfact dealt with acrylic resin
7 Cooling coil header/piping seamless steel pipe, taper pipe welded HVAC special pressureizated seamless steel pipe
8 Drain pan stainless steel,  ( cold-roll steel sheets spray treatment  t1.5mm, optional standard type) corrosion resistance,long product life,clean
9 Rotary heat exchanger sensible, 0.05mm heat exchang aluminum foil high efficient heat exchange, clean-self
10 Primary filter G4 synthetic plate type ,PVC frame non-woven
11 Secondary filter F7 synthetic bag type ,PVC frame non-woven
12 Supply fan/Exaust fan Belt drive multi-blade anteverted centrifugal fan high-quality bearings, good performance,low noise
13 Damper Rubber damper good elastictiy,good vibration reducing performance,low the noise
14 Braid connection  PVC coating B1 flame-proof type
15 Unit base  C type steel surface spraying treatment, high strength, high corrosion resistance
16 Package form  wood pallet, wrapping film  
Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital
Holtop Optional Function Sections Energy Recovery Core Horizontal Ahu Hospital

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier