• Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
  • Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
  • Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
  • Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
  • Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
  • Holtol Dx Coil Air Handling Units with Heat Recovery Ahu

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu

After-sales Service: on-Line Support
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 380/400 VAC
Noise Level: Low
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DX AHU
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
10~15 years
Certification
ISO, CCC
Condition
New
Transport Package
Wooden Pallet
Specification
customized
Trademark
Holtop
Origin
China

Product Description



DX Purification Type Heat Recovery  Air Handling Units
As essences of  Holtop AHU core technology, DX coil AHU provides both AHU and outdoor condensing unit. It's a flexible and typical solution for all building area, such as Mall, Office, Cinema, School etc.
 
                                       
                                         Indoor Unit                         Outdoor Unit
 
 
 
 Holtol Dx Coil Air Handling Units with Heat Recovery AhuHoltol Dx Coil Air Handling Units with Heat Recovery Ahu


Holtol Dx Coil Air Handling Units with Heat Recovery Ahu


 
 
 
 
 
Product name
DX Purification Type Heat Recovery Air Handling Units  
Material
Stainless steel
Function
Heat recovery,adjust cold/heat/humidity
Application
Factory,Mall,Restrant, Hotel,Hospital, School,etc
Filter class
G4+F7+H10
Place of origin
Beijing,China

 

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
 

 

Selection Table of AHU
Holtol Dx Coil Air Handling Units with Heat Recovery Ahu

 

Working principle

1/Both supply fan and exhaust fan are built inside tobring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor space in natural comfort.
2/Built-in heat exchanger (rotary heat exchanger or plate heat exchanger) transfers energy contained in the outgoing indoor air to the coming fresh air,thus fresh air is precooled or preheated.
3/Various functional sections such as filter section,cooling/heating section, humidifying section etc.can be combined together to meet different air treatment requirements.

 

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu

 

Judging left or right type

Look at the direction of airflow supplied to indoor, it's left type if water pipes are located on the left side of the unit; otherwise, it's a right type. For standard AHU, service door, wiring port and water pipe locate on the same side.

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
 

 

Main features

1/ Up-down layer construction, concise, compact.
2/ Rotary heat exchanger(RHE) as a basic part. Humidifying section, coil section etc. selectable as per requirements.

 

Typical Combinations

Combination mode 1:
Wheel + Coarse filter (medium filter) + Cooling coil (heating coil)+ Humidification + Fan

Combination mode 2:
Plate heat exchanger + Coarse filter (medium filter) + Mixed air +Cooling coil (heating coil) + Fan

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
 

 

Rotary heat exchanger (heat recovery wheel) is mainly used in building ventilation or in the air supply/discharge system of air conditioning equipment. The wheel transfers the energy (cold or heat) contained in exhaust air to the fresh air supplied to indoor.It's a piece of important equipment and a key technology in the field of construction energy saving.

 Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
 

 

 

Rotary heat exchanger section

1. Rotary heat exchanger is composed of heat rotor(wheel), frame, drive system, double purge sector and sealing parts etc..
2. Supply air(SA) passes through half of the wheel, exhaust air(EA) passes through reversely the rest half of the wheel, meanwhile the wheel is rotating driven be the drive system. Thus, the wheel can be self-cleaning.
3. Drain pan is equipped under the wheel, in case condensed water occurs from fresh air in summer or return air in winter when their temperature is decreasing. Meanwhile, make sure the drainpipe is expedite and waterseal is installed.

4. Ice jam might occur on the exhaust side when operating in very cold area, if so, rotary speed reduction or turn-on of bypass is required to ensure safe operation of the wheel.
5. On some occasions with strict cleanness requirement, to minimize the carryover from return air to supply air, exhaust fan shall be placed in the leaving section of the exhaust side to create passive pressure, and the pressure shall be lower than that of supply side, so that the double purge sector can perform more effectively.
6. For easy transportation or easy installation in limit space, the wheel can be cut into segments.

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu

                     

FAN SECTION

We offer different types of fans such as direct driven centrifugal fan, belt driven DIDW forward centrifugal fan, and belt driven DIDW backward centrifugal fan etc.

 

Holtol Dx Coil Air Handling Units with Heat Recovery Ahu
 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters