Usage: Residential Ventilation System
Certification: RoHS, ISO, CE
Principle: Recuperative Heat Exchanger
Application: HVAC Ventilation System
Installation: Ceiling Suspensed
Transport Package: Wooden Case
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Specification
200~400CMH
Trademark
Holtop
Origin
Beijing, China
HS Code
8415830000
Production Capacity
500 Sets /Month

Product Description

Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit
Product Description

Temperature humidity total energy recovery fresh air heat exchanger recuperator for greehouse

Fresh air + Energy recovery, reducing running cost of cooling or heating system

 
 

 Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained in normally exhausted building or space air and using it to treat (precondition) the incoming outdoor ventilation air in residential and commercial HVAC systems. During the warmer seasons, the system pre-cools and dehumidifies while humidifying and pre-heating in the cooler seasons. The benefit of using energy recovery is the ability to meet the ASHRAE ventilation & energy standards, while improving indoor air quality and reducing total HVAC equipment capacity.

Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit
Feature of TH series energy recovery ventilator 

1)Airflow from 150-1300m3/h

2)Energy recovery

3) Crossflow heat exchanger

4) Quiet operation

5)Double filters

6)Easy installation to ceiling

7)By-pass function

Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit

Effective Ventilation
Introduces outdoor fresh air into indoors, meanwhile expels the indoor stale air to outdoor, which makes you feel the comfort of nature.


High efficient energy recovery
The built-in high efficient heat exchanger can recover the energy from outgoing indoor air 
to coming fresh air while ventilating. It can recover over 70% energy.
Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit
Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit

Perfect silence design
It is designed with the worldwide fashionable structure and manufactured by the accurate moldings. According to the principle of hydrokinetics, it achieves the perfect silent effect by using the micro-punch anechoic technology.


Air filtration and purification
The inner air filters are professionally designed to remove the pollutants of the incoming air, providing you the fresh and clean air.


By-pass function
By-pass function enables the unit to make natural ventilation in suitable climates, which can prolong the service life of the heat exchanger.

Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit

High airproof feature and easy maintenance
The heat exchanger is connected with the equipment by the in-mold rail, and embedded with the special soft and dense sealing materials. It can be drew out by hand and is easy to maintain. At the same time, it can ensure that the fresh air and exhaust air are completely separated, avoiding the cross pollution.

 

Control system
Optional Intelligent control system, optional CO 2 and humidity control function, external control and BMS control available
Model

Airflow

 m3/h

  

External 

pressure (Pa)

  

Enthalpy

 Efficiency ( %)

     

temp. Eff.

 (% )  

noise dB(A)      

Input 

power (W)

              Summer   Winter               volt. (v) current (A)  
  L M H L M H L M H L M H L M H L M H      
XHBQ-D2TH 150 200 200 60 70 75 60 55 55 63 59 59 75 70 70 25 30 31.5 220 0.5 105
XHBQ-D3TH 250 300 300 75 82 85 62 57 57 65 61 61 73 68 68 27 34 34.5 220 0.56 117
XHBQ-D4TH 350 400 400 80 85 88 62 57 57 65 60 60 74 69 69 31 37 37.5 220 0.72 150
XHBQ-D6TH 500 600 600 89 92 97 63 59 59 67 61 61 76 70 70 29 35 39 220 0.96 200
XHBQ-D8TH 700 800 800 92 96 100 57 55 55 63 57 57 74 68 68 34 39 41 220 1.7 355
XHBQ-D10TH 900 1000 1000 80 85 86 60 58 58 64 62 62 76 70 70 34 38 42 220 2.1 440
XHBQ-D13TH 1000 1300 1300 75 85 90 58 56 56 62 59 59 76 70 70 38 41 43 220 3.4 710
 

About Holtop Factory
Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling UnitFactory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling UnitFactory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit

 
Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit
Factory Price Fresh Air Unit Energy Recovery Ventilation System Air Handling Unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters