Customization: | Available |
---|---|
Usage: | Ventialtion System |
Certification: | ISO, CE, CCC |
Still deciding? Get samples of US$ 200/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
New Eco-smart Plus Energy Recovery Ventilator is upgraded to comply with ERP2018.
The fans built-in are more efficient, energy consumption reduces by up to 50%. The intelligent controller is improved
for more reliable and user friendly operation. Ideal ventilation solutions for energy efficient buildings to
reduce energy consumption while achieving comfort indoor climate.
Feature:
1. Choose the proper installation types based on the building structure
2. Determine the fresh airflow required according to the use, size and number of persons
3. Select the right specifications and quantity according to the determined fresh airflow
Example
The area of a computer room is 60 sq. meters (S=60), the net height is 3 meters (H=3), and there are 10 per-sons (N=10) in it.
If it is calculated according to "Personal fresh air consumption", and assume that: Q=70, the result is
Q1 =N*Q=10*70=700(m3/h)
If it is calculated according to "Air changes per hour", and assume that: P=5, the result is
Q2 =P*S*H=5*60*3=900(m3)
Since Q2 > Q1 , Q2 is better for selecting the unit.
As to special industry such as hospitals (surgery and the special nursing rooms), labs, workshops, airflow re-quired should be
determined in conformity with regulations concerned.
Model |
Rated Air Flow (m3/h) |
Rated E.S.P (Pa) |
Enthaply efficiency % | Temperature | Noise dB(A) | Voltage (V) |
Power Input (W) |
Weight (kg) | |
Cooling | Heating | ||||||||
XHBQ-D1.5DCTPA | 150 | 75 | 63-70 | 70-76 | 75-82 | 31.5 | 220 | 26 | 25 |
XHBQ-D2.5DCTPA | 250 | 85 | 63-73 | 70-75 | 75-82 | 34.5 | 220 | 46 | 29 |
XHBQ-D3.5DCTPA | 350 | 90 | 66-72 | 69-75 | 75-84 | 37.5 | 220 | 60 | 37 |
XHBQ-D5DCTPA | 500 | 100 | 62-74 | 67-75 | 75-86 | 39 | 220 | 88 | 43 |
XHBQ-D6.5DCTPA | 650 | 85 | 62-70 | 68-73 | 75-84 | 39.5 | 220 | 114 | 64 |
XHBQ-D8DCTPA | 800 | 130 | 65-74 | 71-77 | 75-84 | 42 | 220 | 186 | 71 |
XHBQ-D10DCTPA | 1000 | 110 | 65-74 | 71-78 | 75-85 | 43 | 220 | 243 | 83 |
XHBQ-D15DCTPA | 1500 | 75 | 65-74 | 71-77 | 75-84 | 50 | 220 | 372 | 165 |
XHBQ-D20DCTPA | 2000 | 60 | 65-74 | 71-78 | 75-85 | 51.5 | 220 | 486 | 189 |
Holtop is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 2002, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to world class games and Shanghai Expo 2010, works together with domestic and international brands like Midea, Haier, Hitachi, etc.
Holtop cooperate with world famous brand or offer OEM service including Hitachi, LG, McQuay, TRANE, Systemair, Aldes, York, Haier, Gree, MHI Group, Midea, Carrier, Dunham-Bush, etc.