• Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
  • Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
  • Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
  • Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
  • Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv

Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv

Usage: Residential Ventilation System
Certification: RoHS, ISO, CE
Pricinple: Recuperative Heat Exchanger
Application: HAVC Ventilation System
Installation: Ceiling Suspended
Transport Package: Wooden Cases
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Trademark
Holtop
Origin
Beijing, China
HS Code
8415830000
Production Capacity
100000 PCS / Year

Product Description

Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller ErvHOLTOP ERV/HRV

Working principle of Holtop heat and energy recovery ventilator(HRV & ERV)

Holtop heat & energy recovery ventilator can expel the stale air indoor out of room, meanwhile supplying the fresh air outside into the room, by using the advanced heat/energy recovering technology, the energy can exchange taking advantage of the difference of the temperature and humidity between indoor and outdoor air. By this means, it can not only smooth away the problem of indoor pollution, but also saving energy.
Benefit of HOLTOP ERV(energy recovery ventilator)

Brings a continuous supply of fresh air, filtered outside air into the home

Suck indoor environmental contaminants for improved indoor air quality

Pre-cool or pre-heat the fresh air when in summer and winter

Designed to provide comfort in warmer humid climates and transfer incoming humidity back outdoors.

HOLTOP ERV(energy recovery ventilator) suitable for machine room, for classroom, conference room, hotel lobby etc.

HOLTOP energy recovery ventilators keep your home cleaner and healthier.
Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
Product Description

Energy recovery unit ahu equipment heat recovery air handle unit touch screen intelligent controller

Fresh air Supply+ Energy recovery

electricity bills drop by 82%

Holtop Energy Recovery Ventilator is a cost-efficient, sustainable and quick way to reduce global energy consumption and give better indoor air quality (IAQ) and protect buildings, and environment.
Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller ErvEnergy efficiency class of A according to regulation EU.No.1254/2014.
Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv

Feature:
1)Energy saving BLDC motor, 10 speeds control
2)High eficiency enthalpy heat recovery, more comfortable indoor climate
3) Efficiency up to 80%
4) Intelligent control system, optional CO 2 and humidity control function, external control and BMS control available


Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv

5)Double filter alarm, timer alarm or diferent pressure gauge alarm available
6) Auto bypass, intelligent controlled by outdoor temperature
Model Rated Air Flow (m3/h) Rated E.S.P (Pa) Enthaply efficiency % Temperature Noise dB(A) Voltage (V) Power Input (W) Weight (kg)
Cooling Heating
XHBQ-D1.5DCTPA 150 75 63 ~ 70 70 ~ 76 75 ~ 82 31.5 220 ~ 240 26 25
XHBQ-D2.5DCTPA 250 85 63 ~ 73 70 ~ 75 75 ~ 82 34.5 220 ~ 240 46 29
XHBQ-D3.5DCTPA 350 90 66 ~ 72 69 ~ 75 75 ~ 84 37.5 220 ~ 240 60 37
XHBQ-D5DCTPA 500 100 62 ~ 74 67 ~ 75 75 ~ 86 39 220 ~ 240 88 43
XHBQ-D6.5DCTPA 650 85 62 ~ 70 68 ~ 73 75 ~ 84 39.5 220 ~ 240 114 64
XHBQ-D8DCTPA 800 130 65 ~ 74 71 ~ 77 75 ~ 84 42 220 ~ 240 186 71
XHBQ-D10DCTPA 1000 110 65 ~ 74 71 ~ 78 75 ~ 85 43 220 ~ 240 243 83
XHBQ-D15DCTPA 1500 75 65 ~ 74 71 ~ 77 75 ~ 84 50 220 ~ 240 372 165
XHBQ-D20DCTPA 2000 60 65 ~ 74 71 ~ 78 75 ~ 85 51.5 220 ~ 240 4


 Installation:
Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv

 

Holtop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller ErvHoltop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller ErvHoltop Heat Recovery Ventilation System Fresh Air Handling Units with Intelligent Controller Erv
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters