Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Plastics
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
  • Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
  • Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
  • Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
  • Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
  • Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
Find Similar Products

Basic Info.

Model NO.
HJK-E
Corrosion Durability
General
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
10~15 years
Certification
RoHS, ISO, CE
Install Type
Floor
Panel Type
Double Skin
Panel Thickness
25/40/50mm
Heat Recovery Section
Plate Heat Recovery or Wheel
Filter
Coarse:G2, G3, G4; Medium: F5~F8
Heating and Cooling System
Optional
Control System
Optional
Cooling Method
Cooling Coil
Transport Package
Wooden Cases
Specification
ISO9001, ISO14001, OHSAS18001
Trademark
HOLTOP
Origin
Beijing, China
HS Code
8415822000
Production Capacity
800 Sets/ Month

Product Description

Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC
Features of Air Handling Unit, Energy Saving, Fexible Combination

1) Panel Type: Single or Double layers
2) Panel Thickness: 25 / 40 / 50mm
3) Panel heat preservation: High pressure foamed polyurethane, 40Kg/m³
4) Heat Recovery Section: Plate Heat Exchanger or Rotary Heat Exchanger
5) Heating and Cooling System: Optional
6) Control System: Optional
7) Humidifying section: Optional

Working principle of Air Handling Unit, Energy Saving, Fexible Combination

1. Both supply fan and exhaust fan are built inside to Bring in fresh air and exhaust out the stale indoor Air as well, thus to keep indoor space in natural Comfort.

2. Built-in heat exchanger (rotary heat exchanger or Plate heat exchanger) transfers energy contained in The outgoing indoor air to the coming fresh air, Thus fresh air is precooled or preheated.

3. Various functional sections such as filter section, Cooling/heating section, humidifying section etc. Can be combined together to meet different air Treatment requirements.

Housing Construction Features

1. Double skin panel
Double-skin panel sandwiched with high density PU foam, thermal conductivity below 0.01999W/m· Degree, insuring high performance between -40 Degree and +70 Degree.

2. High mechanical strength
Galvanized sheet inner skin, color steel sheet outer skin, strong steel framework, pressure endurance up to 2000PA, suitable for large air application.

3. High air impermeability
Double inlaid sealing to join the frameworks and panels tight, minimizing air leakage.

4. Flexible combination
Designed with 102mm modulus, frameworks and panels are flexible to change according to design Requirements.

Housing series

08A: 25mm thick panel of floor AHU, suitable for 2000~40000CMH.

08B: 40mm thick panel of floor AHU, suitable for 10000~50000CMH.

Modular number and dimension calculation
1) Height(H): 08A H=n*102+40+100(underframe), 08B H=n*102+70+100(underframe)

2) Width(W): 08A W=n*102+40, 08B W=n*102+70
No. Part Name                                     Material Description
1 Unit panel external plate  material is colorful steel sheet t0.4mm, specialized for air conditioning elegant apprearance, dignity, high corrosion resistance
inner plate material is galvanized steel sheet t0.5mm adopt spangle-free
2 Panel heat preservation high pressure foamed polyurethane t 50mm good insulation performance, high strength, foaming ratio 40Kg/m³
3 Other heat preservation polyethylene foaming good insulation performance
4 Unit frame t 1.0mm  colorful steel sheet frame corrosion resistance, long product life,   high strength
5 Copper tube of cooling coil Ø 12.7mm copper tube,   wall thickness 0.41mm phosphorized seamless copper tube, good heat-transfer
 
6 Cooling coil fin Ø 12.7mm copper tube, adopt aluminium foil t0.15mm aluminium foil surfact dealt with acrylic resin
7 Cooling coil header/piping seamless steel pipe, taper pipe welded HVAC special pressureizated seamless steel pipe
8 Drain pan stainless steel,   ( cold-roll steel sheets spray treatment  t1.5mm, optional standard type) corrosion resistance, long product life, clean
9 Rotary heat exchanger sensible, 0.05mm heat exchang aluminum foil high efficient heat exchange, clean-self
10 Primary filter G4 synthetic plate type, PVC frame non-woven
11 Secondary filter F7 synthetic bag type, PVC frame non-woven
12 Supply fan/Exaust fan Belt drive multi-blade anteverted centrifugal fan high-quality bearings, good performance, low noise
13 Damper Rubber damper good elastictiy, good vibration reducing performance, low the noise
14 Braid connection  PVC coating B1 flame-proof type
15 Unit base  C type steel surface spraying treatment, high strength, high corrosion resistance
16 Package form  wood pallet, wrapping film  
 

 
 
Housing specs
(08A)
                                  Dimensions(mm) Airflow (m3/h)
Rotaryheat exchanger (RHE)  
Plate                Heat Exchanger(PHE)
Coil face area (m2)   External
  (Pa)
 
2.5m/s
 
3.0m/s
 
3.5m/s
0609 HRS(T)700 JX(Q)312*312*454-2 0.311 250-400 2799 3358 3918
0710 HRS(T)800 JX(Q)372*372*505-2 0.458 300-420 4122 4946 5771
0712 HRS(T)900 N/A 0.571 300-450 5144 6168 7195
0812 N/A JX(Q)472*472*404-3 0.571 300-450 5144 6168 7195
0913 HRS(T)1100 JX(Q)552*552*438-3 0.838 320-480 7542 9050 10558
0915 HRS(T)1300 JX(Q)552*552*380-4 0.99 350-500 8910 10692 12474
1018 HRS(T)1500 JX(Q)652*652*455-4 1.321 350-550 11889 14266 16644
1218 HRS(T)1600 JX(Q)802*802*454-4 1.728 350-550 15552 18662 21773
1320 HRS(T)1800 JX(Q)1032*1032*402-5 2.057 350-550 18512 22215 25918
1322 HRS(T)2000 JX(Q)1212*1212*370-6 2.413 400-550 21718 26060 30403
1624 HRS(T)2200 JX(Q)1352*1352*402-6 3.073 400-600 27657 33188 38720
1627 HRS(T)2400 JX(Q)1352*1352*455-6 3.495 350-650 31445 37746 44037
 
Housing specs
(08A)
                                    Dimensions(mm) Airflow (m3/h)
Rotaryheat exchanger (RHE)  
                      Plateheat  exchanger
  (PHE)
Coilface area(m2)     External
 
(Pa)
 
2.5m/s
 
3.0m/s
 
3.5m/s
0915 HRS(T)1300 JX(Q)552*552*380-4 0.990 350-550 8910 10692 12474
1018 HRS(T)1500 JX(Q)652*652*455-4 1.321 350-550 11889 14266 16644
1218 HRS(T)1600 JX(Q)802*802*454-4 1.727 350-550 15552 18662 21773
1320 HRS(T)1800 JX(Q)1032*1032*402-5 2.057 350-550 18513 22215 25918
1322 HRS(T)2000 JX(Q)1212*1212*370-6 2.413 350-520 21718 26060 30403
1624 HRS(T)2200 JX(Q)1352*1352*402-6 3.073 350-550 27657 33188 38720
1627 HRS(T)2400 JX(Q)1352*1352*455-6 3.495 350-650 31445 37746 44037
1729 HRS(T)2600 JX(Q)1512*1512*419-7 4.115 380-680 37035 44442 51849
Holtop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVACHoltop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVACHoltop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVACHoltop Air Handling Unit with Heat Recovery Core, Cooling, Heating, Air Conditioning HVAC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier