• Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
  • Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
  • Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
  • Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
  • Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
  • Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

Usage: Ventialtion System
Certification: ISO, CE, CCC
Place of Origin: Beijing, China
Model Number: Xhbq-D2th~Xhbq-D13th
Heat Recovery Type: Total/ Enthalpy
Air Flow: 200~1300CMH
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
XHBQ-D2TH~XHBQ-D13TH
Packaging Details
Twooden Case
Suitable for
Residential and Commercial
Delivery Detail
3weeks
Install Type
Suspened
Heat Recovery Core
Enthalpy Heat Exchanger
Feature Function
by-Pass
Transport Package
Wooden Case
Specification
XHBQ-D2TH~XHBQ-D13TH
Trademark
Holtop
Origin
Beijing, China (Mainland)
Production Capacity
400 Unit/Units Per Month

Product Description


Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

Home mechanical air slim design ERV HRV  heat energy recovery exhaust ventilation system price

Silm B series ERV

Fresh air + Energy recovery, reducing running cost of cooling or heating system


 Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained in normally exhausted building or space air and using it to treat (precondition) the incoming outdoor ventilation air in residential and commercial HVAC systems. During the warmer seasons, the system pre-cools and dehumidifies while humidifying and pre-heating in the cooler seasons. The benefit of using energy recovery is the ability to meet the ASHRAE ventilation & energy standards, while improving indoor air quality and reducing total HVAC equipment capacity.Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

Super slim design, minimizing installation space

Slim ventilators are designed specially for the projects which have very strict ventilator height requirement, compared with the traditional congeneric products, Slim height is 20% off. Access door is at the bottom so maintenance is much easier.


Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal CirculationPM2.5 Purification, health air for home
Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation


High energy recovery efficiency

Holtop crossflow enthalpy exchanger is built in the full Eco-slim series Erv, heat recovery efficiency up to 82% in winter, the allowance of moisture exchange between fresh air and exhaust air make a soft indoor temperature and humidity.

Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

 Energy saving
Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
 Installation:
Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation
Selection Guide

1. Choose the proper installation types based on the building structure

2. Determine the fresh airflow required according to the use, size and number of persons

3. Select the right specifications and quantity according to the determined fresh airflow

Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

Example

The area of a computer room is 60 sq. meters (S=60), the net height is 3 meters (H=3), and there are 10 per-sons (N=10) in it.

If it is calculated according to "Personal fresh air consumption", and assume that: Q=70, the result is

Q1 =N*Q=10*70=700(m3/h)

If it is calculated according to "Air changes per hour", and assume that: P=5, the result is

Q2 =P*S*H=5*60*3=900(m3)

Since Q2 > Q1 , Q2 is better for selecting the unit.

 

As to special industry such as hospitals (surgery and the special nursing rooms), labs, workshops, airflow re-quired should be determined in conformity with regulations concerned.

 Fan 

speed

Airflow 

(m3/h)

External

Pressure 

(Pa)

temp. efficiency

 (% )

Enthalpy efficiency

 (% )

noise 

dB(A)

current 

(A)

input 

power 

(W)

Nen.

W.

cooling Heating cooling Heating (kg)
  H 100 80 67 80 55 65 29.5 0.3 65  
XHBQ-B1.0T/TL M 100 60 67 80 55 65 29 0.28 56 20
  L 65 30 68 81 57 66 22 0.18 35  
  H 150 90 72 80 59 73 31.5 0.45 95  
XHBQ-B1.5PMT/TL M 150 70 72 80 59 73 31 0.43 90 27
  L 120 45 73 82 61 75 23 0.33 70  
  H 250 75 62 73 55 68 34 0.66 136  
XHBQ-B2.5PMT/TL M 250 50 62 73 55 68 33.5 0.6 125 31
  L 210 35 64 75 57 70 26.5 0.42 88  
  H 350 130 65 76 57 68 37 1.03 215  
XHBQ-B3.5PMT/TL M 350 110 65 76 57 68 36.5 1.01 210 42
  L 240 40 68 81 62 73 31 0.66 135


FAQ

1. How to select the suitable models?

Based on the fresh airflow you need. Please send us the room area, room type or application and number of persons, our team will help you select the suitable units.

 

2. What's the difference between Miss Slim series, TH series, DCTP series, PMTH series and DMTH series?

  • Miss Slim series is specially design for the residential houses which required slim size for installation, theairflow rate for Miss Slim series is from 100-350cmh. The access door position and configurations are different with TH series and TP series.
  • TH series is equipped with crossflow heat exchangers, the airflow ranges from 150-1300cmh, with features of silent operation and cost effective.
  • DCTP series is equipped with cross counterflow heat exchangers with higher heat exchange efficient and energy saving DC motor. 
  • PMTH series is featured with PM2.5 filter. 
  • DMTH series is ErP2018 eco design energy recovery ventilator. 

 

3. Why choose Holtop as business partner?

Holtop is the leading manufacturer in China specializing in the production of air to air heat recovery equipments for more than 16 years.

 

Holtop can supply a full range of products, up to 20 series and 200 specifications. The product range mainly covers heat and energy recovery ventilators, rotary heat exchangers, plate heat exchangers and air handling units.

 

Holtop has 400 employees and covers an area of more than 30,000 square meters. Annual production ability of heat recovery equipment reaches 100,000 sets. Holtop supplies OEM products for Midea, LG, Hitachi, McQuay, York, Trane and Carrier. As an honor, Holtop was the qualified supplier for Beijing Olympics 2008 and Shanghai World Exposition 2010.

 

Holtop has established business relationships with major countries in Asia, Europe and North America, and earned a worldwide reputation for providing reliable products, knowledgeable application expertise and responsive support and services. 

 

4. How about the product quality?

 

Holtop assures high quality products with professional R&D team, first-class production facilities and advanced management system. 

 

Holtop owns numeral control machines, national approved labs, and has successfully passed the certifications of ISO9001, ISO14001, OHSAS18001, CE and EUROVENT.

 

All our products are tested 100% before ex-factory to ensure high quality.

Company Information
 

Holtop Factory

Holtop is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 2002, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Beijing Olympic and Shanghai Expo 2010, works together with domestic and international brands like Midea, Haier, Hitachi, etc.
Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal CirculationSlim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation

Holtop partner

Holtop cooperate with world famous brand or offer OEM service including Hitachi, LG, McQuay, TRANE, Systemair, Aldes, York, Haier, Gree, MHI Group, Midea, Carrier, Dunham-Bush, etc.
 

Slim Air Handling Recuperator Fresh Air Ventilation Unit with Internal Circulation



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters