• Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
  • Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
  • Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
  • Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
  • Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
  • Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

Usage: Residential Ventilation System
Certification: ISO, CE, CCC
Principle: Recuperative Heat Exchanger
Application: HVAC Ventilation System
Installation: Ceiling Suspensed
Transport Package: Wooden Case
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Specification
200~400CMH
Trademark
Holtop
Origin
Beijing, China
HS Code
8415830000
Production Capacity
100000 PCS / Year

Product Description

Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
Product Description

Eco design CE certified hotel forced fresh air ventilator unit system with heat recovery

 

Fresh air + Energy recovery, reducing running cost of cooling or heating system

 

 Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained in normally exhausted building or space air and using it to treat (precondition) the incoming outdoor ventilation air in residential and commercial HVAC systems. During the warmer seasons, the system pre-cools and dehumidifies while humidifying and pre-heating in the cooler seasons. The benefit of using energy recovery is the ability to meet the ASHRAE ventilation & energy standards, while improving indoor air quality and reducing total HVAC equipment capacity.

Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

New Eco-smart HEPA Energy Recovery Ventilator is upgraded to comply with ERP2018.

It is built in energy saving BLDC motor, F9 filter, high efficiency enthalpy heat exchanger. Ideal ventilation solution for residential and light commercial projects.

 

Airflow: 150~6000m3/h

Model: XHBQ-D1.5DMTHA~XHBQ-D60DMTHA

1. Energy saving BLDC motor, 10 speeds control
Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
2.Double filter alarm:  timer alarm or different pressure gauge alarm available
Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
3. High efficiency enthalpy heat recovery, more comfortable indoor climate
Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

4. G3+F9 filter, efficiency over 96% to filter the particulate from 2.5μm to 10μm

 

5.Intelligent control system, optional CO 2 and humidity control function, external control and BMS control available
6.Auto bypass, intelligent controlled by outdoor temperature

Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery
Installation:


Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

Model Rated 
Air 
Flow 
(m3/h)
Rated 
E.S.P 
(Pa)
Enthaply efficiency % Temperature
 efficiency %
Noise 
dB(A)
Voltage 
(V)
Power 
Input 
(W)
Weight 
(kg)
Cooling Heating
XHBQ-D1.5DMTHA 150 70 60-65 63-70 75-80 31.5 220-240 38 25
XHBQ-D2.5DMTHA 250 90 62-71 65-73 73-81 34.5 220-240 85 27
XHBQ-D3.5DMTHA 350 140 62-70 65-73 74-82 37.5 220-240 107 33
XHBQ-D5DMTHA 500 110 63-72 67-75 76-84 39 220-240 140 38
XHBQ-D6.5DMTHA 650 100 60-67 65-71 74-82 41 220-240 160 62
XHBQ-D8DMTHA 800 140 63-71 65-73 76-82 42 220-240 188 72
XHBQ-D10DMTHA 1000 140 60-68 62-72 76-82 43 220-240 312 81
XHBQ-D13DMTHA 1300 135 58-71 59-75 74-82 43 220-240 405 81
XHBQ-D15DMTHA 1500 95 63-71 65-73 76-80 50 220-240 700 147
XHBQ-D20DMTHA 2000 115 60-68 62-72 76-82 51.5 220-240 724 167
XHBQ-D26DMTHA 2600 115 58-66 59-75 74-82 55 220-240 810 190
XHBQ-D40DMTHA 4000 230 60-68 61-71 73-81 59 380-400 2140 335
XHBQ-D50DMTHA 5000 260 60-68 61-71 73-81 68 380-400 2630 395
XHBQ-D60DMTHA 6000 300 60-68 61-71 73-81 70 380-400 3030 557

About Holtop

Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat RecoveryEco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

Eco Design CE Certified Hotel Forced Fresh Air Ventilator Unit System with Heat Recovery

 

 

 

 

 

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters