Material: Aluminum
Flow Direction: Cross Flow
Pressure: Low Pressure
Certification: ISO, CE, CCC
Install Type: Suspended Erv
Heat Recovery Core: Cross Counter Flow Plate Heat Exchanger
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
XHBQ-D1.5~20TP
Core Made of
Er Paper
External Static Pressure
34-120PA
Heat Recovery Efficiency
70-80%
Airflow Rate
150~2000CMH
Power Supply
220~230V/50Hz/1phase
Feature Funcion
by-Pass Function
Control System
Remote Standard or Intelligent Contorl
Delivery Date
2 Weeks
Heat Transfer Surface
Plate Heat Exchanger
Structure Material
Aluminum
Transport Package
Wooden Cases
Specification
ISO9001: 2008, ISO14001
Trademark
HOLTOP
Origin
Beijing, China
HS Code
8415830000
Production Capacity
100, 000/Year

Product Description


CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

 

hotel ventilators home ventilation system for heat recovery

Energy recovery ventilation (ERV) is the energy recovery process of exchanging the energy contained in normally exhausted
building or space air and using it to treat (precondition) the incoming outdoor
ventilation air in residential and commercial
HVAC systems. During the warmer seasons, the system pre-cools and dehumidifies while humidifying and pre-heating in
the cooler seasons. The benefit of using energy recovery is the ability to meet the
ASHRAE ventilation& energy standards,
while improving indoor air quality and reducing total HVAC equipment capacity.

CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)
Fresh air + Energy recovery, reducing running cost of cooling or heating system
 

New Eco-smart Plus Energy Recovery Ventilator is upgraded to comply with ERP2018.

The fans built-in are more efficient, energy consumption reduces by up to 50%. The intelligent controller is improved
for
more reliable and user friendly operation. Ideal ventilation solutions for energy efficient buildings to
reduce energy consumption while achieving comfort indoor climate.

CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

Feature:
 

1)Energy saving BLDC motor, 10 speeds control
2)High eficiency enthalpy heat recovery, more comfortable indoor climate
3) Innovative high efficiency counterflow heat exchanger
 
CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

4) Intelligent control system, optional CO 2 and humidity control function, external control
and BMS control available
CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)
5)Multiple auto defrosting mode, outdoor operation temperature down to -15 oC
6) Auto bypass, intelligent controlled by outdoor temperature
CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)
 
Selection Guide

1. Choose the proper installation types based on the building structure

2. Determine the fresh airflow required according to the use, size and number of persons

3. Select the right specifications and quantity according to the determined fresh airflow

CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

Example

The area of a computer room is 60 sq. meters (S=60), the net height is 3 meters (H=3), and there are 10 per-sons (N=10) in it.

If it is calculated according to "Personal fresh air consumption", and assume that: Q=70, the result is

Q1 =N*Q=10*70=700(m3/h)

If it is calculated according to "Air changes per hour", and assume that: P=5, the result is

Q2 =P*S*H=5*60*3=900(m3)

Since Q2 > Q1 , Q2 is better for selecting the unit.

 

As to special industry such as hospitals (surgery and the special nursing rooms), labs, workshops, airflow re-quired should be
determined in conformity with regulations concerned.


 

Model

Rated Air Flow

(m3/h)

Rated E.S.P

(Pa)

Enthaply efficiency % Temperature Noise dB(A) Voltage (V)

Power Input

(W)

Weight (kg)
Cooling Heating
XHBQ-D1.5DCTPA 150 75 63-70 70-76 75-82 31.5 220 26 25
XHBQ-D2.5DCTPA 250 85 63-73 70-75 75-82 34.5 220 46 29
XHBQ-D3.5DCTPA 350 90 66-72 69-75 75-84 37.5 220 60 37
XHBQ-D5DCTPA 500 100 62-74 67-75 75-86 39 220 88 43
XHBQ-D6.5DCTPA 650 85 62-70 68-73 75-84 39.5 220 114 64
XHBQ-D8DCTPA 800 130 65-74 71-77 75-84 42 220 186 71
XHBQ-D10DCTPA 1000 110 65-74 71-78 75-85 43 220 243 83
XHBQ-D15DCTPA 1500 75 65-74 71-77 75-84 50 220 372 165
XHBQ-D20DCTPA 2000 60 65-74 71-78 75-85 51.5 220 486 189

 

 

CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

 

Holtop Factory

Holtop is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 2002, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Shanghai Expo 2010, works together with domestic and international brands like Midea, Haier, Hitachi, etc.
CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)
CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

Holtop partner

Holtop cooperate with world famous brand or offer OEM service including Hitachi, LG, McQuay, TRANE, Systemair, Aldes, York, Haier, Gree, MHI Group, Midea, Carrier, Dunham-Bush, etc.
 

CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)
Holtop products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, Eurovent, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. Etc.

CE Certified Energy Recovery Ventilation System Unit with Counter-Flow Enthalpy Heat Exchanger (XHBQ-D1.5~20TP)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area